Six packages for habitable attics

Composition and thermal resistance R of the entire build-up, at each Wolle thickness between the rafters. Choose the package, enter the surface area and send the request; the optional external membrane is also selected in the request.

The basic package, with Wolle P1500

System 10 Basic

  • Wolle P1500 (λ 0.038) between the rafters, with P800 (5 cm) at the 15 and 25 cm thicknesses
  • Phase 1: Reflectiva Gold beneath the rafters
  • The sealed air layer, minimum 3 cm
  • Phase 2: Reflectiva Multistrat before the plasterboard

Optional: Roof Pro or Roof Optim over the roof boarding.

WolleR, m²·K/WConventional insulation λ 0.038
10 cm5,08219.3 cm
15 cm6,39724.3 cm
20 cm7,71329.3 cm
25 cm9,02934.3 cm
30 cm10,34539.3 cm
Details
The basic package, with Wolle P2100

System 10 Basic+

  • Wolle P2100 (λ 0.035) between the rafters, with P800 (5 cm) at the 15 and 25 cm thicknesses
  • Phase 1: Reflectiva Gold beneath the rafters
  • The sealed air layer, minimum 3 cm
  • Phase 2: Reflectiva Multistrat before the plasterboard

Optional: Roof Pro or Roof Optim over the roof boarding.

WolleR, m²·K/WConventional insulation λ 0.038
10 cm5,30720.2 cm
15 cm6,62325.2 cm
20 cm8,16431.0 cm
25 cm9,48036.0 cm
30 cm11,02141.9 cm
Details
The complete membrane package, with Wolle P1500

System 10 Medium

  • Wolle P1500 (λ 0.038) between the rafters, with P800 (5 cm) at the 15 and 25 cm thicknesses
  • Phase 1: two layers of Multistrat and Gold
  • The sealed air layer, minimum 3 cm
  • Phase 2: Reflectiva Multistrat before the plasterboard

Optional: Roof Optim over the roof boarding.

WolleR, m²·K/WConventional insulation λ 0.038
10 cm5,68621.6 cm
15 cm7,00126.6 cm
20 cm8,31731.6 cm
25 cm9,63336.6 cm
30 cm10,94941.6 cm
Details
The complete membrane package, with Wolle P2100

System 10 Medium+

  • Wolle P2100 (λ 0.035) between the rafters, with P800 (5 cm) at the 15 and 25 cm thicknesses
  • Phase 1: two layers of Multistrat and Gold
  • The sealed air layer, minimum 3 cm
  • Phase 2: Reflectiva Multistrat before the plasterboard

Optional: Roof Optim over the roof boarding.

WolleR, m²·K/WConventional insulation λ 0.038
10 cm5,91122.5 cm
15 cm7,22727.5 cm
20 cm8,76833.3 cm
25 cm10,08438.3 cm
30 cm11,62544.2 cm
Details
The highest-performing package, with Wolle P1500

System 10 Premium

  • Roof Pro or Roof Optim over the roof boarding
  • Wolle P1500 (λ 0.038) between the rafters, with P800 (5 cm) at the 15 and 25 cm thicknesses
  • Phase 1: two layers of Multistrat and Gold
  • The sealed air layer and Multistrat before the plasterboard
WolleR, m²·K/WConventional insulation λ 0.038
10 cm5,98622.7 cm
15 cm7,30127.7 cm
20 cm8,61732.7 cm
25 cm9,93337.7 cm
30 cm11,24942.7 cm
Details
The highest-performing package, with Wolle P2100

System 10 Premium+

  • Roof Pro or Roof Optim over the roof boarding
  • Wolle P2100 (λ 0.035) between the rafters, with P800 (5 cm) at the 15 and 25 cm thicknesses
  • Phase 1: two layers of Multistrat and Gold
  • The sealed air layer and Multistrat before the plasterboard
WolleR, m²·K/WConventional insulation λ 0.038
10 cm6,21123.6 cm
15 cm7,52728.6 cm
20 cm9,06834.5 cm
25 cm10,38439.5 cm
30 cm11,92545.3 cm
Details

Values calculated for the entire build-up, from the Isoflect document “System 10 thermal insulation packages”. “Conventional insulation” is the thickness of an insulation with λ 0.038 that achieves the same thermal resistance R (R × 0.038). The “+” packages use Wolle P2100 (λ 0.035), the others Wolle P1500 (λ 0.038). For Basic, Basic+, Medium and Medium+, the values are for the package without the optional external membrane.

Quote request

Request a quote for the selected package

Choose the package, the Wolle thickness between the rafters and, where applicable, the optional external membrane. Enter the surface area and see the required quantities.

The package

Wolle thickness between the rafters

Exterior membrane

First, choose the package.

Area

Material requirements

    The quantities include 3% for overlaps and waste and are rounded up to whole rolls and packs. For Wolle, the configuration of slabs/rolls is determined according to the predominant clear spacing between rafters.

    Order the sample pack

    Choose the package in order to request a quote.

    In brief

    Three zones, each with its own role

    A well-insulated habitable attic has three zones, each with its own function: under the roof covering, between the rafters and towards the interior. Below you can see which product goes into each zone, exactly where it is installed and what it does. In this way you know from the outset what to purchase and in what order.

    Zone 1 · Under the roof covering

    The diffusion membrane: Roof Pro or Roof Optim

    It is the first layer from the exterior and is laid over the rafters or over the roof boarding, beneath the counter-battens, followed by the battens and the tiles or sheet metal. It allows vapour to escape from the roof and stops water and dust that penetrate beneath the roof covering. Roof Pro has an aluminium foil face, so it adds a radiant barrier directly beneath the roof covering and reflects part of the summer heat; Roof Optim performs the same functions, with an aluminised reflective layer.

    Zone 2 · Between the rafters

    Wolle thermal insulation fibre

    It fills the space between the rafters over their full depth and is installed before the interior membranes. It reduces the heat passing through the mass of the material (conduction), with a thermal conductivity from 0.035 W/mK, and also contributes to sound insulation. It does not settle over time, does not irritate the skin during installation, is cut with a knife and is fitted into the bays without leaving joints.

    λ (W/mK), thermal conductivity: how easily the material conducts heat; the lower it is, the better the material insulates. What this means →
    Zone 3 · Towards the interior

    The reflective package: Gold and Multistrat

    These are the last two layers, which close the build-up. Gold is fixed beneath the rafters once the insulation between them is complete, and Multistrat is placed before the plasterboard or timber panelling. With the sealed air layer between them, they reflect 95–97% of radiation, stop air currents and control vapour; over 10–15 cm of Wolle between the rafters, the System 10 Basic package: the Basic 10 variant (Wolle P1500, 10 cm) reaches R = 5.08 m²·K/W, equivalent to 19 cm of conventional insulation with λ 0.038, and the Basic 15 variant (Wolle P1500 10 cm + P800 5 cm) reaches R = 6.40 m²·K/W, equivalent to 24 cm. In the Basic+ variants (with Wolle P2100), the values are R = 5.31 m²·K/W at 10 cm (20 cm equivalent) and R = 6.62 m²·K/W at 15 cm (25 cm equivalent).

    Advice

    Not sure which build-up suits you?

    Tell us the surface area and the rafter depth, and we will tell you what goes into each layer and in what quantities. You can reach us on 0790 067 438.

    Installation steps

    Click on the central image to enlarge it.

    Installation, step 1: the membrane under the roof coveringInstallation, step 2: the insulation between the raftersInstallation, step 3: reflectiva goldInstallation, step 4: reflectiva multistratInstallation, step 5: the cladding

    In this application

    Products for this application

    Frequently asked questions

    In what order are the layers installed in a habitable attic?

    From the exterior: the diffusion membrane under the roof covering, then Wolle between the rafters, then Gold beneath the rafters and, after the air layer, Multistrat before the plasterboard or timber panelling.

    What is the difference between Roof Pro and Roof Optim?

    Both allow vapour to escape and stop water and dust beneath the roof covering. Roof Pro has an aluminium foil face and adds a radiant barrier beneath the roof covering; Roof Optim does the same, with an aluminised reflective layer.

    How much does the Gold + Multistrat package add to the insulation between the rafters?

    With 10–15 cm of Wolle between the rafters, the System 10 Basic package (Gold and Multistrat): the Basic 10 variant (Wolle P1500, 10 cm) reaches R = 5.08 m²·K/W, equivalent to 19 cm of conventional insulation with λ 0.038, and the Basic 15 variant (Wolle P1500 10 cm + P800 5 cm) reaches R = 6.40 m²·K/W, equivalent to 24 cm. In the Basic+ variants (with Wolle P2100), the values are R = 5.31 m²·K/W at 10 cm (20 cm equivalent) and R = 6.62 m²·K/W at 15 cm (25 cm equivalent).

    The Isoflect sample pack: samples of the membranes and of Wolle
    The sample pack

    See and touch the products before ordering

    The Isoflect sample pack contains samples of the reflective membranes and of Wolle wool insulation, so that you can compare the materials at home or on site.

    Request a quote for your project

    Upload your project

    Share this page

    Send it to someone who is insulating a house. You can also find us on WhatsApp and on social networks.